Data Loggers

The Site is regularly updated so visit again soon.

Latest Software Releases

DaqLab v1.40.01

Release Date: April, 2007

Click here for Release Notes

DaqLink v1.2.2.1 NEW

Release Date: 5 November, 2009

DataNet v2.0.0.0

Click here for Release Notes

Release Date: 30 May, 2010

MicroLab and MicroLab Lite v3.65

Click here for Release Notes

Release Date: 17 November, 2008

Latest Firmware Releases

DataNet 2.31, supporting all DataNet hardware

Click here for Release Notes

Release Date: 17 June, 2010

 

Free Software and Logger Driver Downloads

All software downloads are for Windows OS only

DaqLab

supporting DaqPRO

MicroLab

supporting MicroLog, MicroLogPro, MicroLite

MicroLab Lite

supporting MicroLite

DataNet

Logger Software Drivers

DaqLab 1.40.01 English

 

Upgrade to MicroLab v3.65 *

* supporting upgrade from existing MicroLab v3.64 installations only

v3.65 English

v3.65 Portuguese

v3.64 German

v3.64 Spanish

v3.63 Italian

 

 

Firmware

Download DataNet firmware v2.31

Software

Upgrade to DataNet v2.0

DataNet Release Notes

Click here for software and firmware update instructions

For MicroLog and DaqPRO:

Download driver

Download Driver Installation Guide

For DaqLink, DataNet and MicroLite:

For Windows XP, Vista and 7

User Guides and Calibration Guides

DatPass Admin Software (21 CFR Part 11 Compatible)  

DaqLink

 

DaqPRO

 

DataNet

 

 

MicroLog and MicroLogPRO

MicroLite

 

Discontinued Products

DatPass Administration Software User Guide

DaqLink 1.2.2.1 User Guide

DaqPro and DaqLab User Guide

DataNet v2.0 User Guide

MicroLab User Guide for MicroLog and MicroLogPRO MicroLab Plus User Guide for MicroLog
DatPass and MicroLab Validation Manuals DaqPRO Calibration Instructions

DataNet CFR v2.0 User Guide (21 CFR Part 11 compatible)

MicroLog and MicroLog PRO Temperature and Humidity Calibration Instructions MicroLab Plus User Guide for MicroLogPRO
DatPass and MicroLab Plus Validation Manuals   DataNet v2.0 Installation and Registration Guide MicroLite User Guide TriLink User Guide
DatPass and DataNet

Validation Manuals

  DataNet v2.0 Software and Firmware Update Guide MicroLab Lite Installation Guide
DataNet Calibration Instructions MicroLite Calibration Instructions
GSM Modem User Guide:

Telit EZ10

Wavecom FastTrack Supreme

Cinterion

Sensor Guides

External Sensor – Contact

External Sensor – Current

External Sensor – Temperature

External Sensor – Voltage

Fourier Industry Catalogs and Brochures

Fourier Product Catalog 2009

DaqPRO brochure

DataNet Wireless ZigBee Network brochure

MicroLog System brochure

MicroLite brochure

Software License Agreements

DaqLab

DaqLink

DataNet

DatPass

MicroLab

MicroLab Lite

MicroLab Plus

 

Temperature 10-bit

MicroLogPRO

Compact 10-bit Data Logger

Two data loggers are available:

Temperature plus external sensors

– RH and temperature plus external sensors

The new 10-bit MicroLog has all the benefits of the 8-bit MicroLog in addition to the following innovative new features.

  • Higher sampling resolution for more

    accurate readings

  • Increased memory – 52,000 samples
  • Enhanced 4 digit LCD display

MicroLogPRO 10-bit offers a temperature data logger and combined temperature humidity data logger PLUS external sensors.

Click image to enlargeThis new product is fully featured, enabling its use in a wide range of applications including pharmaceutical; food production and storage; transportation; museums, clean rooms and HVAC, to name a few.

MicroLogPRO Integrates:

  • Thermal portable printer – simply scan MicroLog’s infrared beam external

    sensor input

  • Software – MicroLab automatically saves the data and produces daily status reports of

    your environment.

  • Transmitter – monitoring up to 200 loggers and transmitting data to the PC

Specifications

Click here to view MicroLog Specifications (PDF Format)

 

MicroLog and MicroLogPRO Comparison Table

 

Ordering Code

EC600

EC650

EC700

EC750

Sampling resolution 8 bit 10 bit
Internal Range -30˚C to 50˚C -30˚C to 50˚C (T)

0 to 100% (RH)

-40 to +80˚C -40 to 80˚C

0 to 100% (RH)

Temperature Accuracy ±0.6˚C ±0.2˚C
Humidity Accuracy N/A ±3% N/A ±2%
Resolution 0.5˚C (-30˚C to -29˚C)

0.4˚C (-28˚C to -22˚C)

0.3˚C (-21˚C to 22˚C)

0.4˚C (23˚C to 32˚C)

0.5˚C (33˚C to 39˚C)

0.5% 0.2˚C (-40˚C to -20˚C)

0.1˚C (-21˚C to 50˚C)

0.2˚C (51˚C to 80˚C)

0.1%
Memory capacity 1 sensor – 16000 samples

2 sensors – 8000 samples

3 sensors – 5312 samples

1 sensor – 52000 samples

2 sensors – 26000 samples

3 sensors -16000 samples

Sampling Rate Minimum – 1 per 10 seconds

Maximum – 1 per 2 hours

Output:
LCD Two digit, 7-segments LCD Four digits, 7-segments LCD with decimal point
LCD Units Icons ˚C, ˚F, %RH, Ext ˚C, ˚F, %RH, pH, V, mA, mS, AL-H, AL-L
RS-232 Cable connection to the PC with 19200 kbps
USB – optional N/A N/A USB 1.1

Option for quantities over 200 units with low water & dust protection

USB 1.1

Coming soon

Infrared Printout Minimum, maximum and duration up to 30 days

Wireless report to portable thermal printer HP82240B

Minimum, maximum and duration up to 30 days

OR

Real-time data printout up to 128 last values

OR

Wireless report to portable thermal printer HP82240B

Power Supply Internal Lithium battery 3.6V, 1/2AA, 1.2AH
Battery Life Approximately 24 month (May vary with number of sensors connected and the sampling rate settings)
Dimensions 72mm diameter, 22.9mm thickness
Weight 55g 55g

 

Unisystem Marine Scale

Marine Scaleunisystems_logo.jpg

 

The Marine scale from Unisystem is one-of-its-kind being approved and verified for legal-for-trade catch weighing at sea according to directive 2009/23/EC. The scale is fast, robust, hygienic, easy-to-use and exceptionally accurate. Furthermore, it is durable and designed to withstand heavy wash down conditions. The scale may be used all over the world and no recalibration is needed.

Technical specifications

Capacities 3-150 kg
Platform size 286 x 345 mm
348 x 415 mm
500 x 600 mm
Powered by 230VAC or 12-29VDC
Power consumption 25mA at 230VAC
200mA at 24VDC
Communication RS232 or RS485
Compensation for gravity Gravity Tilt
Sealing IP67
Stainless steel EN 1.4301
Warranty time Two years

 

PDF BROCHURE

eSeaSystem

When using an eSeaSystem you can land your catches not only weighed but also graded, boxed and labeled, ready for sale. The system includes software creating catch reports, with logging, in compliance with EU fishing control regulations. A revolution for the professionals daily operations. Today’s strict requirements for traceability, efficiency and profitability are now possible to live up to – in an easy-to-use and cost effective way.

Fish species and grading

You select the species from a list. The list can be updated at any time, by using the built-in Ethernet connection, switching manually between different lists. In this way, you will be using effective short-lists.

Clever solutions

Operating the system at sea is easy. The buttons are designed to be operated using gloves and the printing labels are feed out of a stainless steel enclosure, making it easy to remove the label after each print.

Durable for long and stormy rides

The system is robust and durable for all harsh and wet conditions, even after long-time use. The scale does not need re-calibration and tilt and movements of the sea does not affect the weighing. It is also compensated for gravitational changes, which means that the ship can go long distances with same high accuracy.

Safely catch reporting

All weighing data are automatically transferred to a computer via network into a catch report. You can always be sure that your data is saved. If your connection is broken all your weighing data will be saved and eSeaSystem ensures that these data are reported as soon as reconnection takes place – automatically!

eSeaSystem allows you to focus on operations rather than on reporting!

Specifications

Rugged IP67
Labels Weight
Fish species
Grading
Date/time
Area
Communication Ethernet, connect to existing network
Catch report Software included for printing or exporting of catch report
Catch logging When Ethernet network is not available, all weighing data will be stored in the controller unit until a new connection is detected.
Approved weighing In compliance to directive 2009/23/EC. Very stable and accurate so no give-away or just-to-make-sure-fish needed.

 

Watch the systems in action